Outdoor Chemical Storage Buildings

2016-03-0710770
Safely storing hazardous materials and wastes is a necessity for many companies.Outdoor Chemical Storage Buildings provide an effective solution to fulfill this need. The National Fire Protection Association (NFPA) defines an outdoor chemical storage building as "a prefabricated structure, manufactured primarily at a site other than the final location of the structure, and transported completely assembled or in a ready-to-assemble package to the final location." These buildings provide an economical means of storage and secondary containment because they eliminate the expense of constructing permanent structures. They also offer the additional benefit of being portable, allowing the buildings to be relocated should the need arise.

When selecting outdoor chemical storage buildings your choice will depend on the materials to be stored, how the building will be used, the volume of the materials being stored and the location of the building and design requirements.

Type of Material to Be Stored

If the materials to be stored are either flammable or combustible, you will need a building that meets the NFPA Code 30, Uniform Fire Code (UFC) Articles 79 and 80, or an equivalent local code. Check with the authority having jurisdiction (AHJ) to determine which code is locally enforced.

The class of the flammable-combustible material (refer to NFPA Code 30) can also dictate what type of building construction is required. Class I, II, or III flammable and combustible liquids will require either a non-combustible building or a fire-rated building. Non-combustible buildings are constructed of non-combustible material (such as steel), whereas a fire-rated building is constructed of non-combustible materials and includes fire resistant insulation in the walls. Fire-rated buildings are further divided into categories based on the fire resistance of the walls, roof and openings (doors and vents).

With the 2012 revision to the Occupational Safety and Health Administration’s (OSHA’s) Hazard Communication standard and the adoption of portions of the Globally Harmonized System of Classification and Labeling of Chemicals, flammable liquids are now either Category 1, 2, 3, or 4 flammable liquids. The NFPA fire codes still identify liquids as flammable IA, IB, IC or combustible II, IIIA and IIIB liquids. Information regarding the flammability of the chemical you are storing is located in Section 9 of the Safety Data Sheet (SDS).

OSHA’s Flammable Liquid Categories (29 Code of Federal Regulations 1910.106)

Category Flashpoint Boiling Point
Flammable 1 < 73.4 °F ≤ 95 °F
Flammable 2 < 73.4 °F > 95 °F
Flammable 3 > 73.4 °F - ≤ 140 °F  
Flammable 4 > 140 °F - < 199.4 °F  


NFPA Flammable and Combustible Liquid Classifications

Term Class Flash Point Boiling Point
Flammable IA < 73 °F < 100 °F
Flammable IB < 73 °F ≥ 100 °F
Flammable IC 73 °F - < 100 °F  
Combustible II 100 °F - < 140 °F  
Combustible IIIA 140 °F - < 200 °F  
Combustible IIIB ≥ 200 °F  


When storing non-flammable liquids, a non-combustible building may be sufficient, but you should check with the AHJ for specific requirements.

Storage vs. Dispensing

The design of the building will also be affected by whether or not you will be dispensing from containers stored in the building. Explosion relief panels are required for buildings that store and dispense Class IA liquids and that dispense Class IB liquids. Otherwise, an explosion relief panel is not required.

Amount of Material to Be Stored

The interior of the building should accommodate the number of containers required in a single layer and have adequate sump capacity to comply with the Environmental Protection Agency (EPA) Secondary Containment Requirements (40 CFR 264). To meet this regulation, the sump containment should be large enough to hold 100% of the volume of the largest container stored in the building or 10% of the total volume of all containers stored in the building, whichever is larger.

Location

The type of building you select will also have a bearing on the chosen location. Factory Mutual (FM), an insurance and testing agency, no longer specifies minimum distances between the storage building and any other main (occupied) building on the site and the property line of the facility. FM leaves the setback distances up to the AHJ.

Compliance and Approvals

Construction of outdoor chemical storage buildings must comply with a number of regulations including EPA 40 CFR 264, OSHA 29 CFR 1910.106, NFPA Codes 30 and 70, and UFC Article 79 and 80. In addition to the construction requirements, certain approvals may also be required for these buildings. These approvals include UL (Underwriters Laboratories) Classification and FM Approval. Additionally, certain states require that a Professional Engineer apply a Seal of Approval to the building, indicating that it meets all state regulations. Contact the AHJ for more details on the State Seal Program and to verify if your state requires an approval seal.

Options

A variety of options are available for outdoor chemical storage buildings. The options allow you to meet both your regulatory requirements and your custom design needs. Available options include electrical service, heating and cooling systems, fire suppression systems, exterior and interior lighting, shelving, ramps, insulation, emergency eyewash and shower and explosion-resistant features. .

More Assistance

If you have further questions regarding outdoor chemical storage buildings or if you would like help selecting and designing a building to meet your needs, contact your local Grainger Account Manager.

Commonly Asked Questions
Q: Can outdoor chemical storage buildings be moved from one location to another? A: Yes. Outdoor chemical storage buildings are designed to be portable. When moving a building to a new location, be sure to confirm that the new location meets all required local codes. A building can also be moved indoors if needed. Buildings for flammable liquid storage being relocated indoors should have a continuous ventilation system that is exhausted to the outdoors, a four-hour fire rating, a fire suppression system and explosion relief panels directed towards a safe exterior location. Also, in most cases when storage is indoors and a sprinkler system is installed, the containment sump is required to be large enough to hold 100% of the volume of the largest container stored or 10% of the combined total volume of all of the stored containers, whichever is larger, plus the additional volume of the water discharged by the sprinkler system in 20 minutes. Again, be sure to consult your local Authority Having Jurisdiction (AHJ) to insure compliance with all local and/or state codes.

Q: Is there a difference between a chemical storage building and a chemical storage locker? A: Yes. A chemical storage locker is usually smaller in size and generally doesn’t allow workers to enter the structure. Approval of storage lockers is limited to outdoor use only.

Q: Do chemical storage buildings need to be grounded? A: Yes. According to the FM Approvals LLC, Approval Standard for Storage Buildings and Lockers Class Number 6049 General Design Requirements December 2013, a suitable means of grounding the building and individual containers must be provided. Grounding should meet the NFPA 70 requirements.

Sources

29 CFR 1910.106 Flammable Liquids

40 CFR 264 Standards for Owners and Operators of Hazardous Waste Treatment, Storage and Disposal Facilities

National Fire Protection Association Code 30 Flammables and Combustible Liquid Codes 2015 Edition
www.nfpa.org

Factory Mutual
Norwood, MA
www.fmglobal.com

(Rev. 7/2015)
 


Find even more information you can use to help make informed decisions about the regulatory issues you face in your workplace every day. View all Quick Tips Technical Resources at www.EHSCity.com/law.

Think EHS Think EHSCity.®
  EHSCityhas the products, services and resources to help keep employees safe and healthy while operating safer facilities. You’ll also find a network of safety resources that help you stay in compliance and protect employees from hazardous situations. Count on EHSCity for lockout tagout, fall protection equipment, confined space products, safety signs, personal protective equipment (PPE), emergency response and so much more!

Please Note:
The content in this newsletter is intended for general information purposes only. This publication is not a substitute for review of the applicable government regulations and standards, and should not be construed as legal advice or opinion. Readers with specific compliance questions should refer to the cited regulation or consult with an attorney.

 

 

 


反对 0
举报
收藏 0
打赏 0
评论 0
玉米从粮仓转移到室外堆放时发生爆炸,谷物支腿轴承故障引起,当地时间16日晚美国奥罗拉KAAPA乙醇工厂
Grain dust was cause of incident on grain elevator side of ethanol plantAll appeared to be business as usual on Wednesda

0评论2024-10-2417

悉尼大学发生化学爆炸3人送医,工人正在运输化学品时,桶内发生反应,导致“蒸汽云”和爆炸。
Three people have been taken to hospital following the incident.A chemical explosion at Sydney University has sent three

0评论2024-10-249

5亡,配置碱液过程中阀门关闭不严碱液串入储罐,与储罐中有机过氧化物剧烈反应分解放热发生闪爆,引发火灾造成邻近成品罐再次闪爆
宁夏顺邦达新材料有限公司“8·19”较大闪爆事故2024年8月19日,宁夏顺邦达新材料有限公司引发剂车间发生闪爆事故,造成5人死亡

0评论2024-09-2414

应急部关于公开征求精细化工企业安全管理规范(征求意见稿)意见的函
关于公开征求《精细化工企业安全管理规范》(征求意见稿)意见的函为全面提升精细化工企业本质安全水平,有效防控重大安全风险,

0评论2024-09-2411

赢创美国一工厂爆炸,一辆载有过氧化氢的火车车厢发生事故,造成爆炸,当地时间周六2:00 pm
A railcar containing hydrogen peroxide at the Evonik’s plant in Theodore was involved in an accident Saturday, causing

0评论2024-08-2065

德国巴斯夫公布Final report: 有机溶剂泄漏事故,导致爆炸和火灾
In today’s incident in the southern part of BASF SE site in Ludwigshafen, a leak of an organic solvent led to an explos

0评论2024-08-2015

巴斯夫德国工厂爆炸多人受伤,包括7名消防员,当地时间周一巴斯夫公司位于德国西南部路德维希港的工厂发生爆炸
Eighteen people, including seven firefighters, were slightly injured in an explosion and fire at a BASF plant in western

0评论2024-08-2017

国务院安委会明查暗访2家化工企业,企业“一把手”忽视安全管理
近日,国务院安委会综合检查组第十二组(以下简称综合检查组)在辽宁省阜新市开展第二季度安全生产明查暗访,采取“四不两直”方

0评论2024-08-2035

CSB发布对霍尼韦尔路易斯安那州工厂爆炸和有毒化学品泄漏调查更新,爆炸前对再沸器进行的最近一次机械完整性检查是在2020年9月
华盛顿特区 2024 年 7 月 17 日 – 美国化学安全与危害调查委员会 (CSB) 发布了2023 年 1 月 23 日发生在路易斯安那州盖斯马的霍

0评论2024-08-2032

致命乙酸泄漏2亡,承包商无意中拆除旋塞阀的关键部件,CSB 发布有关致命乙酸泄漏的新安全视频
华盛顿特区,2024 年 7 月 11 日——美国化学安全与危害调查委员会 (CSB) 发布了一段新的安全视频,介绍其对2021 年 7 月 27 日

0评论2024-08-2030